Ana içeriğe atla
Ürün ayrıntıları İngilizce olarak görüntülenir. Çeviriler yakında gelecek.
Equipment Calibration Management — A build-to-order ERPNext application for managing calibration of gauges, instruments, and  — 1/1Örnek önizleme

A build-to-order ERPNext application for managing calibration of gauges,

instruments, and test equipment with due-date scheduling, certificate storage, and out-of-tolerance handling.

ECOSIRE scopes, builds, installs, and supports it for your bench.

Equipment Calibration Management nedir?

A build-to-order ERPNext application for managing calibration of gauges, instruments, and test equipment with due-date scheduling, certificate storage, and out-of-tolerance handling. ECOSIRE scopes, builds, installs, and supports it for your bench. Built to order by ECOSIRE for ERPNext v15, v16 — indicative price from $999.00 USD; request a quote for a scoped proposal.

Temel Özellikler

Dedicated `Instrument`/`Calibration Equipment` DocType with asset link, serial/tag, location, and responsible metrology role
Per-instrument calibration interval (days/months) with an auto-computed `next_due_date` field
Daily `scheduler_events` hook that recomputes due dates and transitions instruments into Due-Soon / Overdue windows
Reminder notifications (email plus in-desk) enqueued to the responsible role ahead of each due date
`Calibration Event` DocType capturing vendor, reference standard, as-found and as-left readings per measurement point, and verdict
Server-side tolerance validation that blocks submission when as-left readings exceed configured limits without a documented disposition
Out-of-tolerance and overdue status flags with color-coded desk indicators and a calibration dashboard
Optional `validate` lockout hook that prevents Overdue or Out-of-Tolerance gauges from being referenced on Quality Inspection or Work Order operations
Standards and vendor traceability chain linking each calibration to its reference standard and its own calibration certificate
Native Frappe File attachment of calibration certificates with version history and print-format certificate template
Whitelisted REST methods (`@frappe.whitelist()`) exposing calibration status and upcoming-due queries for MES/LIMS/Power BI integration
Role profiles and DocType permission rules separating instrument admin, calibration recording, and lockout-override rights
Audit-logged override workflow so any bypass of a lockout is recorded with user, reason, and timestamp
Client scripts for live tolerance feedback and one-click renewal that schedules the next calibration on submit

Siparişe özel, sizin için baştan sona

Kendiniz kurmanıza gerek yok — ECOSIRE tarafından geliştirilen, kurulan ve desteklenen çalışır bir uygulama.

  1. 1

    Sipariş verirsiniz

    Tek seferlik geliştirme fiyatıyla başlayın. Kapsamı başlangıçta sizinle birlikte belirleriz.

  2. 2

    Geliştirir ve kurarız

    ECOSIRE, ERPNext ortamınızda geliştirir, yapılandırır ve kurar.

  3. 3

    Yayına alma + destek

    Yaklaşık bir iş haftasında yayına alırsınız; canlıya geçiş sonrası iki hafta destek dahildir. Teslim ettiğimiz koddaki hatalar ücretsiz düzeltilir.

Teknik Özellikler

ERPNext Uyumluluğu
—
Lisans
Lisansın doğrulanması gerekiyor
Python Gereksinimi
Python 3.10+
Veritabanı
MariaDB 10.6+

Bu Ürün Hakkında

Quality and metrology teams in regulated or precision manufacturing live and die by calibration status: which gauge is due this week, which instrument drifted out of tolerance, and whether the certificate is on file when the auditor asks. ERPNext core has an Asset DocType and Asset Maintenance schedules, but neither models a calibration interval per instrument, an out-of-tolerance reading, a signed certificate with as-found/as-left values, or a hard lockout that stops an overdue gauge from being used on the shop floor. Most teams end up tracking this in a spreadsheet that lives outside ERPNext, disconnected from the items, work orders, and quality inspections the gauges actually govern.

ECOSIRE builds a proper Frappe application (ecosire_calibration) with its own module and DocTypes rather than bolting fields onto core. The centerpiece is an Instrument (or Calibration Equipment) DocType holding the asset link, calibration interval, tolerance limits, standard/reference traceability, and a computed next_due_date. A Calibration Event DocType captures each calibration: performing vendor, reference standard used, as-found and as-left readings per measurement point, pass/fail verdict, and the certificate file. A hooks.py scheduler event runs daily to recompute due dates, flag instruments crossing into an overdue window, and enqueue reminder notifications to the responsible metrology role. doc_events on the Calibration Event recalculate the parent instrument's status on submit, and a server-side validation blocks submission when as-left readings fall outside the configured tolerance without a documented disposition.

Out-of-tolerance and overdue instruments are made unmissable and, where you need it, enforceable. We add status flags and dashboard indicators, and — for shops that require it — a validate hook on the consuming document (for example a Quality Inspection or Work Order operation) that refuses to reference a gauge whose calibration_status is Overdue or Out of Tolerance, with the block reason surfaced to the operator. Certificates are stored as native Frappe File attachments with version history, and whitelisted REST methods (@frappe.whitelist()) expose calibration status and upcoming-due queries so external MES, LIMS, or Power BI tools can read state over the Frappe REST API. Role profiles and permission rules scope who can register instruments, record calibrations, and override a lockout, with every override written to the audit trail.

Because this is build-to-order, nothing ships as a one-click marketplace download. After a short scoping call we confirm your instrument taxonomy, tolerance and interval rules, certificate template, lockout enforcement points, and target version (ERPNext v15 or v16). We build against a staging bench, run UAT with your metrology team, then install on your instance with a documented rollback plan. Typical delivery is one working week from confirmed scope. You receive the full source repository, so the app is yours to keep, extend, and maintain.

Ne elde edeceksin

  • Installable source code of the `ecosire_calibration` Frappe app for your confirmed ERPNext v15 or v16 version
  • Installation and configuration on your instance (intervals, tolerance rules, lockout points, role profiles)
  • Technical documentation: DocType schema, hooks, whitelisted methods, and scheduler events
  • User guide plus a live training session for your metrology and quality team
  • UAT on a staging bench with a documented, tested rollback plan before production install
  • Post-go-live support window for defect fixes and configuration adjustments
  • Git repository handover so the application is yours to keep and extend
  • Certificate print-format template and sample dashboard configured for your instrument set

Bu kimin için

Quality / Metrology Manager

Owns the master gauge list and the audit outcome. Needs a single source of truth for due dates, certificates, and out-of-tolerance history inside ERPNext, with reminders that fire before instruments lapse rather than a spreadsheet nobody updates.

Calibration Technician / Lab Coordinator

Records each calibration event, enters as-found/as-left readings, and attaches certificates. Wants fast data entry with live tolerance feedback and one-click scheduling of the next due date on submit.

Production / Shop-Floor Supervisor

Cannot afford to run an inspection with a lapsed gauge. Relies on the lockout flags that stop an Overdue or Out-of-Tolerance instrument from being used on a Quality Inspection or Work Order operation, with a clear reason at the point of use.

Quality / Compliance Auditor

Verifies traceability to reference standards and the completeness of certificate records. Needs the audit trail of overrides and the linked standards chain to satisfy ISO 9001, IATF 16949, or ISO/IEC 17025 evidence requests.

Equipment Calibration Management Nasıl Karşılaştırılır

KriterECOSIREÖzel YapıRakipERPNext Yerleşik
Calibration due-date modelPer-instrument interval with auto-computed next-due and scheduler-driven statusWhatever you build; often incomplete on first passGeneric maintenance schedule, rarely calibration-specificAsset Maintenance schedules, no calibration interval concept
Out-of-tolerance handlingAs-found/as-left validation with tolerance block and dispositionPossible but must be designed and tested from scratchUsually a status field, no reading-level validationNot modeled at all
Overdue lockout enforcement`validate` hook stops lapsed gauges on inspections/operationsAchievable with in-house hooks developmentTypically flags only, no enforcementNo lockout mechanism
Certificate and standards traceabilityFile attachments, version history, reference-standard chainDepends on scope and effort investedBasic attachment, limited traceabilityGeneric file attach, no standards chain
Version fit (v15/v16)Built and tested against your confirmed versionDepends on your team's Frappe expertiseCompatibility varies by publisherCore, but lacks the feature set
Integration surfaceWhitelisted REST methods for MES/LIMS/Power BIMust be designed and secured yourselfGeneric REST only, no purpose-built endpointsStandard REST on core DocTypes only
Ownership and supportFull source handover plus post-go-live support windowYou own it and you maintain it entirelyVendor-locked, subscription updatesFrappe community support only
Time to valueone working week from confirmed scope, UAT + rollback planWeeks to months depending on internal capacityFast install but usually needs rework to fitImmediate but no calibration capability

Equipment Calibration Management hakkında Sıkça Sorulan Sorular

Is this an existing app I can download and install today?

No. This is a build-to-order ERPNext application. ECOSIRE scopes it to your instrument taxonomy, tolerance rules, and enforcement points, then builds, installs, and supports it. There is no instant marketplace download.

How long does delivery take?

Typical delivery is one working week from confirmed scope. After a short scoping call we agree the DocType fields, interval and tolerance rules, certificate template, and lockout points; the timeline runs from the point that scope is signed off, and complex integrations can extend it.

Which ERPNext versions are supported?

We build for ERPNext / Frappe v15 and v16. We confirm your exact version during scoping and develop against a matching staging bench so the app installs cleanly on your instance.

How does the out-of-tolerance lockout actually work?

Each instrument carries a `calibration_status`. A `validate` hook on the documents you choose (for example Quality Inspection or a Work Order operation) refuses to reference an Overdue or Out-of-Tolerance gauge and shows the reason. An audit-logged override role can bypass it when your process requires.

Can it integrate with our other systems?

Yes. The app exposes whitelisted REST methods for calibration status and upcoming-due queries over the Frappe REST API, so MES, LIMS, or Power BI can read state. Deeper two-way integrations are scoped as part of the build.

What about support and updates after go-live?

Every build includes a post-go-live support window for defect fixes and configuration tweaks. Because you receive the full git repository, your own team can maintain and extend it, and ECOSIRE offers ongoing support and version-upgrade engagements separately.

Do we own the source code?

Yes. We hand over the complete `ecosire_calibration` app repository. The application is yours to keep, run, modify, and extend without licensing lock-in.

Teklif isteyin

Equipment Calibration Management

A build-to-order ERPNext application for managing calibration of gauges, instruments, and test equipment with due-date scheduling, certificate storage, and out-of-tolerance handling. ECOSIRE scopes, builds, installs, and supports it for your bench.

  • Dedicated `Instrument`/`Calibration Equipment` DocType with asset link, serial/tag, location, and responsible metrology role
  • Per-instrument calibration interval (days/months) with an auto-computed `next_due_date` field
  • Daily `scheduler_events` hook that recomputes due dates and transitions instruments into Due-Soon / Overdue windows
  • Reminder notifications (email plus in-desk) enqueued to the responsible role ahead of each due date

Teklif isteyin

Equipment Calibration Management ihtiyaçlarınızı bize anlatın; fiyatları, lisans seçeneklerini ve size özel bir teklifi genellikle bir iş günü içinde gönderelim.

Şimdi ödeme yok. Bu, ekibimize bir teklif talebi gönderir — fiyat ve sonraki adımlarla e-posta ile dönüş yapacağız.